KYN28-24 Indoor Armored Metal-Enclosed Switch Equipment
1.Rated Voltage:24kV. 2.Rated Frequency:50Hz. 3.Rated current:630/1250/1600/2000/2500/3150/4000A. 4.Installation method: floor-mounted or installed in a prefabricated outdoor box. 5.ApplicableAdd to Inquiry -
24kV Contact Box
1. Rated Voltage: 24kV. 2. Rated Current: 630/1250/1600/2000/2500/3150A. 3. Compatible Cabinet: Suitable for KYN28A-24 type cabinets.. 4. Product Advantages: High insulation and reliability,OptimizedAdd to Inquiry -
WSK Temperature And Humidity Controller
1.Working units:two units .. 2.Control system:One-way humidity monitoring; one-way temperature monitoring.. 3.Mounting Method: Embedded, DIN-rail mounting.. 4.Related Electrical Components: For useAdd to Inquiry -
40.5kV Post Insulator
1.Rated voltage:40.5kV. 2.Creep distance:≥1256mm. 3.Bending failure load:6kN. 4.Power frequency withstand voltage:95kV/min . 5.Lightning impulse withstand voltage:185kV. 6.Installation method:Add to Inquiry -
40.5kV Shielding Bushing
1. Rated Voltage: 40.5kV. 2. Installation Method: Penetrate into cabinets or between the cabinet and other grounded objects.. 3. Compatible Cabinets: Compatible with KYN61-40.5 switchgear.. 4.Add to Inquiry -
Contact Box for KYN61-40.5
1. Rated Voltage: 40.5kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinets: Suitable for KYN61-40.5Add to Inquiry -
Contact Box for KYN28-24
1. Rated Voltage: 24kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinet: Suitable for KYN28A-24 typeAdd to Inquiry -
Contact Box for KYN28-12
1. Rated Voltage: 12kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinets: Suitable for KYN28A-12 typeAdd to Inquiry -
Fixed Contact for Vacuum Circuit Breaker
1.Fixed contacts for vacuum circuit breaker. 2.Good electrical conductivity. 3.High contact reliability. 4.Stronger abrasion resistance. 5.Good insulation properties. 6.Adaptability to theAdd to Inquiry -
12kV Sensor
1. Rated Voltage: 12kV. 2. Installation Method: Vertically or horizontally mounted within the cabinet and between conductive components.. 3. Compatible Cabinets: Suitable for KYN28A-12 typeAdd to Inquiry -
24kV Bushing Insulator
1. Rated Voltage: 24kV. 2. Installation Method: Penetrate into cabinets or between the cabinet and other grounded objects.. 3. Compatible Cabinets: Compatible with KYN28A-24 switchgear.. 4. ProductAdd to Inquiry -
JN22-40.5 Indoor Grounding Switch
1.Rated Voltage: suitable for 40.5kV and below AC power system. 2.Rated Frequency: 50Hz . 3.Rated short time withstand current 31.5kA. 4.Rated withstand current (peak):80 kA . 5.Installation method:Add to Inquiry
KYN28-24 armored removable AC metal closed switchgear cabinet system three-phase AC 50Hz, rated voltage 24kV indoor complete set of power distribution equipment. As power plants,...
KYN28A-24 (z) series armored removable AC metal switchgear is a power distribution equipment for 20kV three-phase AC 50 (60) Hz single bus and single bus sectional system....
Oct 21, 2024 · KYN28-24(ZK)(GZS1) Armoured withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switchgear”) is suitable for three-phase AC 50Hz power systems for...
Jan 5, 2017 · KYN28-24 24KV Armored Removable AC Metal Enclosed Switchgear is suitable for three-phase AC 50/60Hz power system, used to receive and distribute electrical energy, and...
Applicable to the power plant, substation and airports, docks, factories and enterprises, hotels, financial executives and civil construction indoor power supply system, as the acceptance and...
The KYN28-24(Z) Series Armored Withdrawable AC Metal-Enclosed Switchgear, designed for 20V three-phase AC 50(60)Hz single busbar and single busbar sectionalizing systems, serves as a comprehensive...