ZN85-40.5 Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Floor handcart type.. 4. Compatible Cabinet: Compatible with KYN61 switchgear with widths ofAdd to Inquiry -
VTZ-12CL Series Indoor Fault Fast-cutting Vacuum Circuit ...
1.Rated Voltage:12kV. 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated power-frequency withstand voltage:48(Common value) /42(Across the isolating kV. Distance). 5.Rated lighting impulseAdd to Inquiry -
VSM-12 Indoor Permanent Magnetic Vacuum Circuit Breaker
1.Rated Voltage:12kV. 2.Rated Frequency:AC50-60Hz . 3.Applicable cabinets: KYN28-12 series switchgear, XGN-12 fixed cabinets, HXGN-12 series ring-net cabinets. 4.Product compliance standards:Add to Inquiry -
VS1-12 630A Vacuum Circuit Breaker With Lateral Operating...
1. Rated Voltage: 12kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Ring main fixed cabinet.. 4. Compatible Cabinet: Compatible with HXGN-12 series ringAdd to Inquiry -
VS1-24 Vacuum Circuit Breaker With Lateral Operating Mech...
1. Rated Voltage: 24kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Ring main fixed cabinet.. 4. Compatible Cabinet: Compatible with HXGN-12 series ringAdd to Inquiry -
VS1-24 630A 25KA Vacuum Circuit Breaker
1. Rated Voltage: 24kV. 2. Operating Mechanism: Spring Operating Mechanism.. 3. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet: Compatible with KYN28-24 seriesAdd to Inquiry -
VTZ-12C Vacuum Circuit Breaker with Lateral Operating Mec...
1. Rated Voltage: 12kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Ring main fixed cabinet.. 4. Compatible Cabinet: Compatible with HXGN-12 series ring main unit..Add to Inquiry -
ZN85-40.5K Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Integrated Operating Mechanism.. 3. Installation Method: Fixed installation.. 4. Compatible Cabinets: Compatible with XGN series or other welded andAdd to Inquiry -
VS1-24 Vacuum Circuit Breaker
1. Rated Voltage: 24kV. 2. Operating Mechanism: Spring Operating Mechanism.. 3. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet: Compatible with KYN28-24 seriesAdd to Inquiry -
VTZ-24 Vacuum Circuit Breaker
1 VTZ-24 vacuum circuit breaker performance. 2 Simple and convenient maintenance. 3 High conductivity. 4 Wide range of use. 5 Support intelligent customizationAdd to Inquiry -
VTZ-17.5 Vacuum Circuit Breaker
1.Rated Voltage: 17.5kV. 2.Rated Frequency : 50/60HZ. 3.Operating Mechanism: Modular Mechanism. 4.Installation Method: Center Mounted Hand Truck or Fixed Cabinet . 5.Compatible Cabinet: KYN28-17.5Add to Inquiry -
VTZ-12(K59) Vacuum Circuit Breaker
1. Rated Voltage:12kV. 2. Operating Mechanism:Modular operating mechanism.. 3. Installation Method:Floor handcart type.. 4. Compatible Cabinet:Compatible with K-37,K-47,KPH-3,K-3-02,KPH-4-1-10Add to Inquiry
The ZN85-40.5/T2000-31.5 indoor HV vacuum breaker(short for breaker)is used for switching on/off load current, over load current, fault current in industrial and mining establishments,...
WebZN85-40.5 / T (3AV3)-type indoor high voltage vacuum circuit breakers for three-phase AC 50Hz, 40.5KV power system, for industrial and mining enterprises, power plants and...
Jan 05, 2017 · Summary ZN85-40.5 (3AV3) indoor high voltage vacuum circuit breaker is of rated voltage 40.5kV, three-phase and AC 50/60Hz. It applies to...
Zn85-40.5 Indoor Vacuum Circuit Breaker - Manufacturers, Factory, Suppliers from China Our rewards are reduce selling prices,dynamic revenue team,specialized QC,sturdy...
WebZN85-40.5 Vacuum Circuit Breakers ZN85-40.5 Vacuum Circuit Breakers ... Insulators. Polymer Insulators; Bushing Insulators; Supporting Insulators; Support-pin insulators; Composite Insulators; ......
Summary ZN85-40.5 (3AV3) indoor high voltage vacuum circuit breaker is of rated voltage 40.5kV, three-phase and AC 50/60Hz. It applies to mining firms, power house and substation acting as protection...