Our goal is to become your true partner in the field of chassis truck for vcb in China. Shaanxi West Power Tongzhong Electrical Co., Ltd. is a leading manufacturer with over 20 years of experience, specializing in high quality vacuum circuit breakers, switchgears, and a wide range of electrical products. We have a skilled engineering team dedicated to refining every stage, from product development and process improvement to production oversight, ensuring every product delivered meets rigorous quality and performance standards. The price is competitive and the product is quality-assured, which is a good choice for your long-term cooperation.

 

 
  • Intelligent Electric Drop-out Fuses

    Intelligent Electric Drop-out Fuses

    1.Rated voltage:12kV2.Rated frequency:50Hz3.Three core functions:short-circuit/overload protection, visible isolation, and no-load switching
    Add to Inquiry
  • CD Aluminum Electrolytic Capacitor

    CD Aluminum Electrolytic Capacitor

    Products Description CD aluminum electrolytic capacitors are polarized, high-capacity, high-voltage aluminum electrolytic capacitors primarily used for closing energy storage, opening control, and DC
    Add to Inquiry
  • JZ7 Contact Relay

    JZ7 Contact Relay

    1.Rated insulation voltage:380V. 2.Rated operating current:10A/20A/40A/60A/100A/150A(sub-model). 3.Operating Voltage Range:AC 50Hz/60Hz, up to 380V (some models support 660V). 4.Coil Control
    Add to Inquiry
  • CJT1 Series AC Contactor

    CJT1 Series AC Contactor

    1.Rated insulation voltage:380V. 2.Rated operating current:10A/20A/40A/60A/100A/150A(sub-model). 3.Operating Voltage Range:AC 50Hz/60Hz, up to 380V (some models support 660V). 4.Coil Control
    Add to Inquiry
  • AMJ Series Busbar Clamp

    AMJ Series Busbar Clamp

    Products Description AMJ series busbar clamps are made of high-quality unsaturated polyester molded plastic DMC or SMC. They have high strength, excellent insulation performance, and high flame
    Add to Inquiry
  • Electronic Circuit Breaker

    Electronic Circuit Breaker

    1.Rated working voltage: 400V. 2.Rated working voltage 630A. 3.Installation method: vertical installation, horizontal installation;. 4.Applicable environment: below 2000 meters above sea level,
    Add to Inquiry
  • Thermal Magnetic Circuit Breaker

    Thermal Magnetic Circuit Breaker

    1.Product characteristics: small size, high breaking rate, short arcing;. 2.Product function: distribute electric energy and protect lines and power equipment;. 3.Installation method: vertical
    Add to Inquiry
 
Why Choose Us
 

Our R&D: Our R&D team consists of senior technical experts with decades of experience in the design and manufacture of high and low voltage electrical equipment. Their expertise, combined with our advanced facilities, enables us to always lead industry trends and continuously optimize our product portfolio.

 

Quality control: We are able to accurately and efficiently produce a wide range of high-quality electrical products that comply with GB 1984-2024 and GB/T11022-2020 standards to ensure the highest quality.

 

Customization requirements: We know that our customers' needs are different, so each product can be designed according to the specific needs of the customer.

 

Our services: In the pre-sales stage, our team of experts will recommend the most suitable products according to the needs of customers and provide detailed technical consultation. During the sales period, we ensure timely delivery and provide installation guidance. For after-sales, we provide long-term technical support, warranty services and spare parts to help customers maximize the use of products and get reliable maintenance during use.

 

Advantages of LV Components

 
 
01
 

Safety first

Circuit breakers prevent electrical overloads that can be the cause of events like fire, equipment damage, or personal injury. The system automatically shuts off when it detects an irregularity to protect itself and keep operating safely protect it from harm and to keep it operating.

 
02
 

Overload protection

Sometimes, an electrical system can draw more current than it should. A circuit breaker protects the system from this overload by cutting off the extra current, which helps prevent potential fires caused by overheating.

 
03
 

Life of equipment

Electrical surges and short circuits can go a long way in significantly cutting the life of your devices. A circuit breaker helps protect expensive equipment by cutting off power during such events.

Electronic Circuit Breaker

 

Specification of LV Components

 

 

FSpecification of LV Components rame current Imn (A)

160

250

400

630

Type

160M

160H

250M

250H

400H

630H

Serious

3,4

3,4

3,4

Rate current In(A)

12~32,5~63,40~100,63~160

100~250

200~400

400~630

Rated operational voltage Ue(V)

400

400

 

Rated insulation voltage Ui(V)

AC1000

AC1000

 

Rated impulse withstand voltage Uimp (kV)

8

8

 

Rated ultimate short-circuit breaking capacity Icu(kA)

35

65

50

70

50

85

Rated breaking capatity of running short circuit

20

50

35

50

25

50

Rated short time withstand current 1s Icw kA

-

-

-

-

5

8

Use classes

A

Operation cycle times

Electrify on

6000

3000

2000

1500

No electricity off

9000

7000

4000

4000

Outline Dimension(mm)

A-b-c-caproductcate-103-63

Level 3

90-155-77-103

105-165-76-104

147-257-103-155

Level 4

120-155-77-103

140-165-76-104

184-257-103-155

Electric operating mechanism

Manual operating mechanism

 

Types of LV Components

 
 

MCB (Miniature Circuit Breaker): Appraised current not in excess of 100 A. Excursion attributes are typically not customizable. Breakers outlined above are in this classification.

 
 

MCCB (Molded Case Circuit Breaker): Appraised current up to 2500 A. Warm or warm attractive activity. Excursion current might be customizable in bigger evaluations.

 
 

Magnetic circuit breakers: Magnetic circuit breakers use a solenoid (electromagnet) that is pulling power increments with the current. Certain plans use electromagnetic powers notwithstanding those of the solenoid. The electrical switch contacts are held shut by a lock.

 
 

Thermal magnetic circuit breakers: Thermal magnetic circuit breakers, which are found in most conveyance sheets, fuse the two procedures with the electromagnet reacting promptly to huge floods in the current (short-circuits) and the bimetallic strip reacting to less limit yet longer-term over-current conditions.

 
 

Common trip breakers: When providing a branch circuit with more than one live conductor, each live conductor should be ensured by a breaker post. To guarantee that all live conductors are hindered when any post outings, a “typical excursion” breaker should be utilized.

 
 

Medium-voltage circuit breakers: Medium-voltage circuit breakers highlighted somewhere in the range of 1 and 72 kV might be collected into metal-enclosed switchgear lineups for indoor use, or might be singular parts introduced outside in a substation.

 
 

High-voltage circuit breakers: Electrical power transmission networks are secured and constrained by high-voltage circuit breakers.

 
 

Sulfur hexafluoride (SF6) high-voltage circuit-breakers: A sulfur hexafluoride electrical switch uses contacts encompassed by sulfur hexafluoride gas to eliminate the bend.

 

 

Features of LV Components

 

 

Thermal magnetic circuit breaker,with rated insulation voltage up to 690v (630 frame 1000v, suitable for ac 50hz), rated working voltage 400v, and rated working current up to 630a, are used in power distribution network circuits. They are used to distribute electric energy and protect lines and power equipment from losses caused by overload, short circuit, undervoltage and other faults. They can also be used as infrequent starting and overload/short circuit and undervoltage protection for motors. The product has the characteristics of small size, high breaking rate, short arcing, etc. It can be installed vertically or horizontally.

 

Application of LV Components
 
 

Industrial

Protect heavy machinery and sensitive equipment in factories and manufacturing plants. Used in control panels to manage power distribution across production units.

 
 
 

Residential

Protect household wiring and appliances from overloads and short circuits, preventing potential fires. Offer adjustable protection and remote signaling for enhanced safety and control.

 
 
 

Commercial

Safeguard office equipment, HVAC systems, and lighting networks in commercial buildings. Provide protection against faults in large-scale wiring systems, minimizing downtime and potential damage.

 

 

Production Process of LV Components

 

Initial design print

Using a special plotter printer, a “film” or “image” of each layer is made. This film is a photo negative of the board itself. Each layer of the circuit board (both inner and outer) and accompanying solder mask top and bottom get its own layer.

Inner layer copper print and etching

The design is printed onto a laminate material and then copper is pre-bonded to it. The copper is then etched away to reveal the traces and copper fill regions as dictated by the gerber files.

Stackup layer alignment

After each layer has been printed and cleaned, technicians use an “optical punch” and drive a pin through the layers to align them.

Lamination

For multilayer boards, this process consists of applying high heat and pressure to the internal layers of the board while using a photosensitive dry resist.

Hole drilling

Based on the files, a computer-guided drill is used to create registration, guiding, and other specified holes.

Plating

A chemical process is used to create a micron-thick layer of copper over the top layer and the holes that have been drilled, creating vias, whether they be through-hole, blind, or buried.

Outer layer imaging and etching

A photoresist is applied to the outside layers and then imaged. They are then plated similarly to the previously discussed inner layers, with an additional layer of tin to help protect the copper during the etching process.

Soldermask

A solder mask film (usually green) is applied to the surface of the board. Ultraviolet light is then shined on the board to indicate sections for removal.

Silkscreen

The final additive process to the circuit board is the application of the silkscreen or legend. This is used to convey company id numbers, warning labels, component designators, pin locators, or any other useful information.

 

Packing and Shipping of Amber Glass Lunch Box

 

 

Packing

Box

Shipping

Shipped by road, sea, rail

 

FAQ

 

Q: What does an electronic circuit breaker do?

A: A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by current in excess of that which the equipment can safely carry (overcurrent). Its basic function is to interrupt current flow to protect equipment and to prevent fire.

Q: How to fix a circuit breaker that keeps tripping?

A: A circuit breaker that keeps tripping usually indicates an overloaded circuit or a short circuit. To fix this, first, identify the tripped breaker (it will be in the middle or slightly off-center position).

Q: How do you know when a circuit breaker is bad?

A: A circuit breaker is likely bad if it trips frequently, won't reset, has a burning smell, feels hot to the touch, or shows physical damage like scorch marks.

Q: How do I find out what is tripping my electric breaker?

A: Start by turning off all the lights, appliances, and electronic devices in your home. Then, reset the main circuit breaker by switching it off and on. Afterward, turn on each circuit one at a time, and observe which one trips the breaker. Once you've identified the circuit, you can focus on narrowing down the problem.

Q: How do I find out what is tripping my electric breaker?

A: Start by turning off all the lights, appliances, and electronic devices in your home. Then, reset the main circuit breaker by switching it off and on. Afterward, turn on each circuit one at a time, and observe which one trips the breaker. Once you've identified the circuit, you can focus on narrowing down the problem.

Q: How do you know if a circuit breaker needs to be replaced?

A: A circuit breaker likely needs replacement if it frequently trips, shows physical damage, emits burning smells, or feels unusually hot to the touch. Other signs include flickering lights, poor appliance performance, or the breaker not staying reset after being tripped.