Duckbill Contact for Vacuum Circuit Breaker
1.Rated Voltage: Applicable to power equipment with rated voltage of 12kV, 24kV and 40.5kV. 2.Connection method: Stable electrical connection is achieved through parallel upper and lower bite contactAdd to Inquiry -
VS1 Opening And Closing Coil (tripping Electromagnet)
1.Operating voltage:DC220V,DC110V. 2.Resistance (Ω):198、150、31.5. 3.Wire diameter (mm):0.21、0.23、0.31. 4.Actuation travel:33mm . 5.Number of turns:5650、5320、2660 . 6.Mechanical lifespan: ≥ 10,000Add to Inquiry -
VTZ-12 Indoor Phase-controlled Vacuum Circuit Breaker
1.Rated Voltage:12kV. 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated short-circuit breaking current:25/31.5 kA. 5.Rated-short-circuit making current (peak):63/80 kA. 6.MechanicalAdd to Inquiry -
VTZ Locking Electromagnets
1.Voltage:DC 220 DC 110 V. 2.Wire diameter:0.05 0.07mm. 3.Number of turns:31000 16000 N. 4.Resistance:12000±960 4500±360Ω . 5.Movement range:7.5~8mm. 6.Product Advantages:High Reliability,QuickAdd to Inquiry -
ZN28K-12 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: It can be installed in fixed switchgear or box-type switchgear for use.. 4. Compatible Cabinet:Add to Inquiry -
VTZ/CS-12 Vacuum Circuit Breaker with Lateral Operating M...
1. Rated Voltage: 12kV. 2. Operating Mechanism: Lateral operating mechanism.. 3. Installation Method: Side-mounted removable high voltage switchgear.. 4. Compatible Cabinet: Compatible with KCY1-12Add to Inquiry -
K18-7.2(F-C) Indoor Combination Appliance
1. Rated Voltage: 3.6kV to 7.2kV. 2. Installation Method: Floor handcart cabinet.. 3. Compatible Cabinet: Compatible with KYN18C-12 switchgear in a parallel F-C circuit structure.. 4. ProductAdd to Inquiry -
FK(R)N-12 Load Break Switch and Combination Appliance
1.Rated Voltage :12kV. 2.Rated Frequency:50/60Hz. 3. Rated breaking current:1200A. 4. Mechanical endurance :2000A. 5.Installation method: side-mounted fixed installation. 6.Applicable cabinet:Add to Inquiry -
Contact Box for KYN28-24
1. Rated Voltage: 24kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinet: Suitable for KYN28A-24 typeAdd to Inquiry -
Fixed Contact for Vacuum Circuit Breaker
1.Fixed contacts for vacuum circuit breaker. 2.Good electrical conductivity. 3.High contact reliability. 4.Stronger abrasion resistance. 5.Good insulation properties. 6.Adaptability to theAdd to Inquiry -
Tulip Contact for Vacuum Circuit Breaker
1.Rated Voltage: Applicable to power equipment with rated voltage of 12kV, 24kV and 40.5kV . 2.Connection method: Stable electrical connection through annular contact design, highly conductiveAdd to Inquiry -
VTZ-12F Generator Output-Specific Vacuum Circuit Breaker
1. Rated Voltage:15kV. 2. Operating Mechanism: Integrated operating mechanism.. 3. Installation Method: Floor handcart fixed installation.. 4. Compatible Cabinet: Special fixed cabinet from the XGNAdd to Inquiry
LYA406 1600A Duckbill contact vacuum circuit breaker high voltage extension spring flat contact This product is a special dynamic and static contact for vacuum circuit breakers. It is made of...
The working principle of the vacuum circuit breaker is that once the circuit breaker contact is disconnected in a vacuum, the contact is ionized by the metal vapor in the contact and...
The contact fingers are intended for electrical current transm ission and disconnection from a circuit breaker to a switchgear panel by providing a contact finger-trap....
Oct 6, 2024 · 1600A Duckbill Contact Vacuum Circuit Breaker High Voltage Extension Spring Flat Contact US$38.00-55.00 / Piece 2 Pieces (MOQ)...
The contact box is formed by epoxy with APG Technology. 1. Insulation protection: The epoxy resin contact box is used to isolate the live parts inside the switch cabinet to prevent arc and short...
Nov 15, 2023 · Tulip contact is the main contact used to break or turn on the circuit, while fixed contact is used to support and fix the plummer contact, and also can play a certain role in breaking...