FK(R)N-12 Load Break Switch and Combination Appliance
video
FK(R)N-12 Load Break Switch and Combination Appliance

FK(R)N-12 Load Break Switch and Combination Appliance

1.Rated Voltage :12kV
2.Rated Frequency:50/60Hz
3. Rated breaking current:1200A
4. Mechanical endurance :2000A
5.Installation method: side-mounted fixed installation
6.Applicable cabinet: HXGN-12 series ring network cabinet
7.Product compliance standards: GB 3804-2004, GB 16926-1997, IEC 420-1990;
Send Inquiry
Product Introduction

FK (R)N12-12 type indoor AC high-voltage load switch (fuse combination) is a three-phase high-voltage switch with rated power of 12KV and rated frequency of 50Hz, which is suitable for distribution offices and substations of industrial and mining enterprises. It is used as the protection and control of electrical equipment for dividing load current, closed-loop current, no-load transformer and cable charging current. Hybrid short-circuit current. Load switches equipped with ground switches can withstand short-circuit current. Equipped with manual and motor operating mechanism, easy to achieve the power system engineering three remote control requirements.

 

 
 
Product Specifications

 

Specification Sheet

Table1

No.

Name

Unit

Data

 

1

Rated Voltage

kV

12

 

2

Rated Frequency

Hz

50/60

 

3

Rated current

A

≤630(fuse≤125A)

 

4

Rated powder frequency withstand voltage

kV

48(Across the contact gaps)/42 (TO ground)

 

5

Rated lightning impulse withstand voltage

kV

                                                 75

 

6

Rated prospective short-circuit breaking current (fuse)

kA

31.5

 

7

Rated short time withstand voltage peak

kA

50

 

8

Rated short time withstand voltage

kA

20

 

9

Rated short-time withstand current duration

s

2

 

10

Rated breaking current

A

1200

 

11

Mechanical endurance

A

2000

 
 
 
Mechanical characteristics

Table2

No.

Name

Unit

Data

1

Travel

mm

210±4

2

Overtravel

mm

≥40

3

Inherent opening time of shunt release

ms

≤100

4

Main circuit resistance

μΩ

≤300

5

Closing no-simultaneity of 3-phase contacts

ms

≤10

6

opening no-simultaneity of 3-phase contacts

ms

≤5

7

Maximum operating torque for manual operation

N.m

≤160

8

Isolation break distance

mm

≥175

 
Scope of Application
 

FK(R)N-12 Load Break Switch and Combination Appliance has many scope of application:

 

 
Power distribution stations and substations for industrial and mining enterprises;
 
User terminals of box-type substations;
 
User terminals of box-type substations;
 
Product Advantages

FK(R)N-12 Load Break Switch and Combination Appliance has many advantages:

01.

Stable and reliableperformance,compact structure and small size

The product adopts compressed air arc extinguishing, with stable and reliable performance.The switch body and operating mechanism are integrated into one, integrating isolating switch, load switch and grounding switch, with compact structure and small size.

02.

Complete the operation in a single step

Direct-acting isolating break, high dynamic and thermal stable current parameters; unique linkage according to the prescribed operating procedures, one-time operation.

03.

prevent misoperation

Compressed air load switch, grounding switch, valve, switch cabinet door are strictly interlocked according to the "five protections" mechanical interlock to prevent misoperation, safe and reliable.

04.

Realizing the "three remote" requirements.

The spring energy storage operating mechanism can be opened and closed electrically or manually, which is convenient for realizing the "three remote" requirements.

 
Product Outline Drawing

 

 

 

FKRN-12 Load Break Switch and Combination Appliance figure1 price

   Figure 1 Formal installation on the right side

FKRN-12 Load Break Switch and Combination Appliance figure 2 quotation

Figure2 Formal installation on the left  side

Remark:

1. In addition to the above two standard shapes, FKRN12-12 series can be installed upside down according to the actual use;

2. FKRN12-12 can also cancel the grounding knife, or fuse.

 
Secondary Wiring Diagram
 

FKRN-12 Load Break Switch and Combination Appliance factory

 

NO

 Code name

 Name

 Quantity

Remark

1

XT

Wire connecting terminal

1

TD660V-15A

2

KA1

closing relay

1

Hh54p

3

KA2

 Opening relay

1

Hh54p

4

U1,U2

Rectifier silicon bridge

2

KBPC3510

5

TQ

tiripping electromagnet

1

 

6

M

 Energy storage motor

1

59ZY-CJ02

7

SL3,SL2,SL1

  Microswitch

3

LXW2-11

8

DF

  Auxiliary switch

1

FK10-10                                                                                                                                                   

 Figure 3: Electric operation wiring diagram

 

FKRN-12 Load Break Switch and Combination Appliance supplier

NO.

Code name

Name

Quantity

 Remark

1

HK

Auxiliary switch

1

F10-10

2

U1

 Single-phase rectifier bridge

1

KBPC2510

3

TQ

Single-phase rectifier bridge

1

 

4

XT

Terminal Blocks

1

TD660V-15A

                                                                                                                                                          Figure 4: Manual operation wiring diagram

 

Hot Tags: fk(r)n-12 load break switch and combination appliance, China fk(r)n-12 load break switch and combination appliance manufacturers, suppliers, factory, ZW32 12 Outdoor Vacuum Circuit Breaker, lv components, moving contact for vcb, chassis truck for vcb, VTZ 12 Vacuum Circuit Breaker, CT 58 Aviation Connector