Thermal Magnetic Circuit Breaker

Thermal Magnetic Circuit Breaker

1.Product characteristics: small size, high breaking rate, short arcing;
2.Product function: distribute electric energy and protect lines and power equipment;
3.Installation method: vertical installation, horizontal installation;
4.Product compliance standards: IEC60947-2, GB14048.2 and other standards;
Send Inquiry
Product Introduction

Thermal Magnetic Circuit Breaker,with rated insulation voltage up to 690V (630 frame 1000V, suitable for AC 50Hz), rated working voltage 400V, and rated working current up to 630A, are used in power distribution network circuits. They are used to distribute electric energy and protect lines and power equipment from losses caused by overload, short circuit, undervoltage and other faults. They can also be used as infrequent starting and overload/short circuit and undervoltage protection for motors. The product has the characteristics of small size, high breaking rate, short arcing, etc. It can be installed vertically or horizontally.

 

Product Specifications

 

Frame grade

Trip type

Interior Accessories

Rated current (A)

Use

Level 4 optional code

Installation

125

0:No protection

1:Magnetic protection

2: Thermal protection

3:Thermal magnetic protection

See attached table

16,20,32,40,50,63,80,100,125

1. Power distribution

2. Electric motor

A:  N level without protection, can be divided

B:N level without protection, can not be divided

Q: Front of board

H: Back of board

C: Insert

160

100,125,160

250

160,180,200,225,250

400

250,315,350,400

630

400,500,630

Model

ETKM6-125M

ETKM6-160M

ETKM6-160H

ETKM6-250M

ETKM6-250H

Frame grade Imn (A)

125

160

250

Number of poles

1,2,3,4

3,4

Rated current In (A)

16,20,32,40,50,63,80,100,125,

100,125,160

160,180,200,225,250

Rated operating voltage Ue (V)

230(1P)

400

Rated insulation voltage Ui (V)

1000

690

Rated impulse withstand voltage Uimp (kV)

8

Rated ultimate short-circuit breaking capacity

Icu (kA)

25

25

35

35

50

Rated operating short-circuit segmentation capacity

20

20

25

25

35

Use Category

A

Operation cycle times

Power on,

5000

3000

3000

No power on

9000

7000

7000

Release device type

Alarm does not trip

Yes

Thermal trip

Yes

Magnetic trip,

Yes

Thermal-magnetic trip

Yes

Installation wiring method

Front panel wiring

Yes

Rear panel wiring

Yes

Plug-in wiring

Yes (Except 1P and 2P )

Internal accessories

Auxiliary contact

Yes (Except 1P and 2P)

Alarm contact

Yes (Except 1P and 2P)

Shunt release or undervoltage release

Yes (Except 1P and 2P)

External accessories

Electric operating device

Yes (Except 1P and 2P)

Manual operating handle

Yes (Except 1P and 2P)

Terminal cover

Yes (Except 1P and 2P)

 

Outline Dimension

a-b-c-ca (mm)product-151-113

1P

25-130-61-82

-

2P

50-130-61-82

-

3P

75-130-61-82

90-155-77-103

105-165-76-104

4P

100-130-61-82

120-155-77-103

140-165-76-104

 

 

Product Advantages

Thermal Magnetic Circuit Breaker has many advantages:

 

 

 

The product has small size

 

 

 

 

 

high breaking rate and short arcing

 

 

 

 

Withstands humid air

 

 

 

 

Can work reliably in earthquake conditions

product application 

 

Thermal Magnetic Circuit Breaker is used to rated insulation voltage up to 690V (630 frame 1000V, suitable for AC 50Hz), rated working voltage 400V, and rated working current up to 630A  in power distribution network circuits.

  Product outline drawing 

 
 
 
 

Thermal Magnetic Circuit Breaker price

Thermal Magnetic Circuit Breaker quotation

Hot Tags: thermal magnetic circuit breaker, China thermal magnetic circuit breaker manufacturers, suppliers, factory, GGD AC Low Voltage Distribution Cabinet, specific vacuum circuit breaker, 12kV Insulator, VTZ CS 12 Vacuum Circuit Breaker with Lateral Operating Mechanism, indoor mv vacuum circuit breaker, 24kV Phase Column Component

(0/10)

clearall