VTZ-12 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet: Compatible with KYN28-12Add to Inquiry -
VTZ-12DM Indoor Single-phase Permanent Magnet Vacuum Circ...
1.Rated Voltage:12kV. 2.Rated Frequency:AC50-60Hz . 3.Applicable cabinets: KYN28-12 series switchgear, XGN-12 fixed cabinets, HXGN-12 series ring-net cabinets. 4.Product compliance standards:Add to Inquiry -
LTZ-40.5 Indoor High Voltage SF6 Circuit Breaker
1. Product name: SF6 circuit breaker. 2. Rated Voltage: 40.5kV. 3. Rated Current: 1250A. 4. Rated short-circuit breaking current:31.5kA. 5. Rated power frequency withstand voltage :95 kV/1min. 6.Add to Inquiry -
VS1-24C Indoor Vacuum Circuit Breaker
Rated Voltage:24kVRated Frequency:50/60HzRated current:630/1250/1600A1.Rated power-frequency withstand voltage:65kV. 2.Installation method: Ring network fixed cabinet. 3.Applicable cabinet:HXGN-24Add to Inquiry -
VTZ-12 1250A Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Rated Current:1250A. 3. Operating Mechanism: Modular operating mechanism.. 4. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet:Add to Inquiry -
12kV 630A-5000A Vacuum Circuit Breaker
1.Rated Voltage: 12kV. 2.Operating Mechanism: Modular operating mechanism. 3.Installation Method: Center-mounted handcart or fixed cabinet installation. 4.Compatible Cabinets: Compatible withAdd to Inquiry -
VS1-12 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Handcart with a central operating mechanism or fixed cabinet.. 4. Compatible Cabinet:Add to Inquiry -
VS1-12 Vacuum Circuit Breaker with Lateral Operating Mech...
1. Rated Voltage: 12kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Ring main fixed cabinet.. 4. Compatible Cabinet: Compatible with HXGN-12 series ringAdd to Inquiry -
VTZ-40.5K Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular Operating Mechanism.. 3. Installation Method: Fixed installation.. 4. Compatible Cabinet: Compatible with XGN series or other 40.5kVAdd to Inquiry -
ZN12-12 Vacuum Circuit Breaker
1.Rated Voltage:12kV. 2.Rated Frequency:AC50-60Hz . 3. Operating Mechanism:3AF type manufactured by Siemens, Germany. 4. Installation Method:Floor type handcart or fixed cabinet. 5. CompatibleAdd to Inquiry -
VTZ-17.5 Vacuum Circuit Breaker
1.Rated Voltage: 17.5kV. 2.Rated Frequency : 50/60HZ. 3.Operating Mechanism: Modular Mechanism. 4.Installation Method: Center Mounted Hand Truck or Fixed Cabinet . 5.Compatible Cabinet: KYN28-17.5Add to Inquiry -
ZN39-40.5 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Modular mechanism. 3. Installation: floor withdrawable type. 4. Suitable for cabinet: suitable for JIN1-35, GBC-35 switchgear.. 5. Products followAdd to Inquiry
Reliability, safety and performance in a compact package . The new and extensive line of W-VACi compact MV vacuum circuit breakers with IEC ratings of 12 kV, 17.5 kV and 24 kV are part of...
FXK6 series AC vacuum contactor is suitable for AC 50Hz ~ 60Hz, the rated working voltage of the main loop is 1.5kVOr 3.6kV and below in the power system, used to make and break the...
Model No.: VTZ2-12/630-25. Brand: Shaanxi West Power. Breaking Capacity: High Voltage Circuit Breakers. Operation: Energy-storage Type. Speed: High-Speed Circuit Breaker. Arc...
VTZ-12 Series of indoor Vacuum Circuit Breaker adopt new type operating mechanis and embedded poles. This structure makes the VCB mechanical...
W-VACi vacuum circuit breakers are equipped with high speed, high energy operating mechanisms. They are designed with several built-in interlocks and safety features to provide...
Model No.: VTZ-12/4000-50. Brand: Shaanxi West Power. Breaking Capacity: High Voltage Circuit Breakers. Operation: Manual Type. Speed: High-Speed Circuit Breaker. Arc...