VTZ-40.5K Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular Operating Mechanism.. 3. Installation Method: Fixed installation.. 4. Compatible Cabinet: Compatible with XGN series or other 40.5kVAdd to Inquiry -
VTZ-40.5 Indoor Fast Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Center-mounted trolley or fixed cabinet.. 4. Compatible Cabinet: KYN61-40.5 seriesAdd to Inquiry -
VTZ-12CL Series Indoor Fault Fast-cutting Vacuum Circuit ...
1.Rated Voltage:12kV. 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated power-frequency withstand voltage:48(Common value) /42(Across the isolating kV. Distance). 5.Rated lighting impulseAdd to Inquiry -
VTZ-12DM Indoor Single-phase Permanent Magnet Vacuum Circ...
1.Rated Voltage:12kV. 2.Rated Frequency:AC50-60Hz . 3.Applicable cabinets: KYN28-12 series switchgear, XGN-12 fixed cabinets, HXGN-12 series ring-net cabinets. 4.Product compliance standards:Add to Inquiry -
VS1-12 1250A Vacuum Circuit Breaker With Lateral Operatin...
1. Rated Voltage: 12kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Ring main fixed cabinet.. 4. Compatible Cabinet: Compatible with HXGN-12 series ringAdd to Inquiry -
VTZ-12 630A Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Rated Current:630A. 3. Operating Mechanism: Modular operating mechanism.. 4. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet:Add to Inquiry -
12kV Vacuum Circuit Breaker With Lateral Operating Mechanism
1. Rated Voltage: 12kV. HXGN-12 series ring main unit. 5. Product Compliance with Standards: Complies with GB/T1984-2014 and G2. Operating Mechanism: Modular operating mechanism. 3. InstallationAdd to Inquiry -
12kV 630A-5000A Vacuum Circuit Breaker
1.Rated Voltage: 12kV. 2.Operating Mechanism: Modular operating mechanism. 3.Installation Method: Center-mounted handcart or fixed cabinet installation. 4.Compatible Cabinets: Compatible withAdd to Inquiry -
VTZ-12 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Center-mounted handcart or fixed cabinet.. 4. Compatible Cabinet: Compatible with KYN28-12Add to Inquiry -
VS1-12 Vacuum Circuit Breaker
1. Rated Voltage: 12kV. 2. Operating Mechanism: Integrated frame operating mechanism.. 3. Installation Method: Handcart with a central operating mechanism or fixed cabinet.. 4. Compatible Cabinet:Add to Inquiry -
ZN85-40.5 Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Floor handcart type.. 4. Compatible Cabinet: Compatible with KYN61 switchgear with widths ofAdd to Inquiry -
ZN85-40.5 Miniaturized Vacuum Circuit Breaker
1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Floor handcart type.. 4. Compatible Cabinet: Compatible with KYN61 switchgear with widths ofAdd to Inquiry
· Rated voltage: 33kV, 35kV, 36kV, 40.5kV · Rated current: 630-4000A · Short-circuit breaking current: 20-40kA · Short-circuit closing current(peak): 50-100kA · Installation type: Draw-out type. ·...
ZW7-40.5 type of outdoor high voltage vacuum circuit breaker is three-phase ac frequency 50 Hz, rated voltage of 40.5 kV outdoor high voltage switch equipment....
Model No.: VTZ-40.5/T1250-25. Brand: Shaanxi West Power. Breaking Capacity: High Voltage Circuit Breakers. Operation: Electric Type. Speed: High-Speed Circuit Breaker. Arc-extinguishing Medium:...
VTZ-40.5/T type indoor vacuum circuit breaker for three- phase AC 50Hz, 40.5kV power system, for industrial and mining enterprises, power plants and substations. The circuit breaker use of...
Vacuum circuit-breakers of type VD4 are intended for indoor installation in air-insulated switchgear. The circuit-breakers of column design with a rated voltage of 36 kV and 40.5 kV...
Maximize your productivity with reduced downtimes with ABB’s flagship product family of VD4 circuit breakers for primary and secondary protection, with a global installed base of over 2...