40.5kV Phase Column Component
1.40.5kV phase column component vertically mounted on 24kV circuit breaker frame;2.Improvement of electrical insulation performance3.Enhanced mechanical protection4.Easy to install andAdd to Inquiry -
KYN28-12 Indoor Armored Metal-Enclosed Switch Equipment
Production Description KYN28-12 indoor armored metal-enclosed switch equipment (hereinafter referred to as KYN28-12 switchgear) is suitable for three-phase AC 50HZ, 7.2~17.5kV single busbar andAdd to Inquiry -
WSK Temperature And Humidity Controller
1.Working units:two units .. 2.Control system:One-way humidity monitoring; one-way temperature monitoring.. 3.Mounting Method: Embedded, DIN-rail mounting.. 4.Related Electrical Components: For useAdd to Inquiry -
40.5kV Shielding Bushing
1. Rated Voltage: 40.5kV. 2. Installation Method: Penetrate into cabinets or between the cabinet and other grounded objects.. 3. Compatible Cabinets: Compatible with KYN61-40.5 switchgear.. 4.Add to Inquiry -
RN8 Gas Insulation Ring-Network Switchgear Cabinet
1.Rated current:12KV and 24KV . 2.Rated frequency: 50Hz. 3.Main busbar rated current:630A. 4.Insulation and arc extinguishing medium:SF6 . 5.The operating mechanism:Sring type 6.Scope ofAdd to Inquiry -
Contact Box for KYN61-40.5
1. Rated Voltage: 40.5kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinets: Suitable for KYN61-40.5Add to Inquiry -
Contact Box for KYN28-24
1. Rated Voltage: 24kV. 2. Installation Method: Vertically installed at the rear of the cabinet, connected and assembled with the primary busbar.. 3. Compatible Cabinet: Suitable for KYN28A-24 typeAdd to Inquiry -
40.5kV Sensor
1. Rated Voltage: 40.5kV. 2. Installation Method: Vertically or horizontally mounted within the cabinet and between conductive components.. 3. Compatible Cabinets: Suitable for KYN61-40.5 typeAdd to Inquiry -
24kV Sensor
1. Rated Voltage: 24kV. 2. Installation Method: Vertically or horizontally mounted within the cabinet and between conductive components.. 3. Compatible Cabinets: Suitable for KYN28A-24 typeAdd to Inquiry -
40.5kV Insulator
1. Rated Voltage: 40.5kV. 2. Installation Method: Vertically or horizontally mounted within the cabinet and between conductive components.. 3. Compatible Cabinet: Compatible with KYN28A, XGN, JYN,Add to Inquiry -
12kV Insulator
1. Rated Voltage: 12kV. 2. Installation Method: Vertically or horizontally mounted within the cabinet and between conductive components.. 3. Compatible Cabinet: Compatible with KYN28A, XGNAdd to Inquiry -
KYN28-24 Indoor Armored Metal-Enclosed Switch Equipment
1.Rated Voltage:24kV. 2.Rated Frequency:50Hz. 3.Rated current:630/1250/1600/2000/2500/3150/4000A. 4.Installation method: floor-mounted or installed in a prefabricated outdoor box. 5.ApplicableAdd to Inquiry
ET2 is an indoor installed 40.5kV armored removable air-insulated switchgear, which is suitable for three-phase AC 50Hz single bus section system, including 630~3150A current rating....
Vd4 36kv 40.5kv Vacuum 3 Phase Circuit Breaker 2000A Power Vd4 Vcb Vacuum Circuit Breaker High Voltage Switchgear Indoor 12kv 13.8kv 24kv 35kv US$10,000.00-20,000.00 / Piece 1...
KYN61-40.5 removable AC metal-clad switchgear applies to 40.5kV, 3 phase, AC and 50/60Hz electrical power network for receiving and distributing power energy and also for control,...
LBS405 COMPONENTS Hughes LBS405 load break switch for 33/40kV has the following components: • ABB VG10 2000A/20kA 40.5kV vacuum interrupter (1); • Integrated 3x phase...
KYN61-40.5 Air insulated metal clad movable switchgear is an indoor switchgear, assembly operating under the conditions of 50/60Hz three phase and rated 40.5kV AC voltage, which is...
ET2 product is an indoor installed 40.5kV armored removable air-insulated switchgear, which is suitable for three-phase AC 50Hz single bus breaking system, including 630~3150A series...