• 24kV Contact Box

    24kV Contact Box

    1. Rated Voltage: 24kV. 2. Rated Current: 630/1250/1600/2000/2500/3150A. 3. Compatible Cabinet: Suitable for KYN28A-24 type cabinets.. 4. Product Advantages: High insulation and reliability,Optimized
    Add to Inquiry
  • VTZ-12 Series Indoor Phase-selective Switching Intelligent Vacuum Circuit Breaker

    VTZ-12 Series Indoor Phase-selective Switching Intelligen...

    1.Rated Voltage:12kV . 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated short-circuit breaking current:25/31.5kA. 5.Rated-short-circuit making current (peak):63/80kA6.Rated withstand
    Add to Inquiry
  • VTZ-40.5 Indoor Fast Vacuum Circuit Breaker

    VTZ-40.5 Indoor Fast Vacuum Circuit Breaker

    1. Rated Voltage: 40.5kV. 2. Operating Mechanism: Modular operating mechanism.. 3. Installation Method: Center-mounted trolley or fixed cabinet.. 4. Compatible Cabinet: KYN61-40.5 series
    Add to Inquiry
  • VTZ-12CL Series Indoor Fault Fast-cutting Vacuum Circuit Breaker

    VTZ-12CL Series Indoor Fault Fast-cutting Vacuum Circuit ...

    1.Rated Voltage:12kV. 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated power-frequency withstand voltage:48(Common value) /42(Across the isolating kV. Distance). 5.Rated lighting impulse
    Add to Inquiry
  • VTZ-12DM Indoor Single-phase Permanent Magnet Vacuum Circuit Breaker

    VTZ-12DM Indoor Single-phase Permanent Magnet Vacuum Circ...

    1.Rated Voltage:12kV. 2.Rated Frequency:AC50-60Hz . 3.Applicable cabinets: KYN28-12 series switchgear, XGN-12 fixed cabinets, HXGN-12 series ring-net cabinets. 4.Product compliance standards:
    Add to Inquiry
  • VS1 Opening And Closing Coil (tripping Electromagnet)

    VS1 Opening And Closing Coil (tripping Electromagnet)

    1.Operating voltage:DC220V,DC110V. 2.Resistance (Ω):198、150、31.5. 3.Wire diameter (mm):0.21、0.23、0.31. 4.Actuation travel:33mm . 5.Number of turns:5650、5320、2660 . 6.Mechanical lifespan: ≥ 10,000
    Add to Inquiry
  • JZ7 Contact Relay

    JZ7 Contact Relay

    1.Rated insulation voltage:380V. 2.Rated operating current:10A/20A/40A/60A/100A/150A(sub-model). 3.Operating Voltage Range:AC 50Hz/60Hz, up to 380V (some models support 660V). 4.Coil Control
    Add to Inquiry
  • CJT1 Series AC Contactor

    CJT1 Series AC Contactor

    1.Rated insulation voltage:380V. 2.Rated operating current:10A/20A/40A/60A/100A/150A(sub-model). 3.Operating Voltage Range:AC 50Hz/60Hz, up to 380V (some models support 660V). 4.Coil Control
    Add to Inquiry
  • VTZ-12 Indoor Phase-controlled Vacuum Circuit Breaker

    VTZ-12 Indoor Phase-controlled Vacuum Circuit Breaker

    1.Rated Voltage:12kV. 2.Rated Frequency:50/60Hz. 3.Rated current:630/1250A. 4.Rated short-circuit breaking current:25/31.5 kA. 5.Rated-short-circuit making current (peak):63/80 kA. 6.Mechanical
    Add to Inquiry
  • AMJ Series Busbar Clamp

    AMJ Series Busbar Clamp

    Products Description AMJ series busbar clamps are made of high-quality unsaturated polyester molded plastic DMC or SMC. They have high strength, excellent insulation performance, and high flame
    Add to Inquiry
  • WSK Temperature And Humidity Controller

    WSK Temperature And Humidity Controller

    1.Working units:two units .. 2.Control system:One-way humidity monitoring; one-way temperature monitoring.. 3.Mounting Method: Embedded, DIN-rail mounting.. 4.Related Electrical Components: For use
    Add to Inquiry
  • DSW4G Series Outdoor Electromagnetic Lock

    DSW4G Series Outdoor Electromagnetic Lock

    1.Applicable voltage level: 10kV and above. 2.Operating voltage: 110/220V. 3.Power-on time: ≤ 10s. 4.Operating environment: -40°C to 40°C. 5.Altitude: ≤ 2500m. 6.Product application: Substation
    Add to Inquiry

(0/10)

clearall