Blog

Home/Blog/Details

Why vacuum circuit breaker is used?

People use vacuum circuit breaker to regulate high voltage currents. They are ideal for demonstrating loss of opposite phase current and double earth faults. Vacuum circuit breakers are well suited for use in power stations and generators. People also use vacuum circuit breakers in railroad applications because of their ability to switch traction currents and power supplies.

In addition, VCBs are also used in metal-clad switchgear. Differences between Vacuum Circuit Breakers (VCBs) and Air Circuit Breakers (ACBs) Both Vacuum Circuit Breakers (VCBs) and Air Circuit Breakers (ACBs) offer valuable features. However, they have a number of differences, as follows:

Voltage Applications

Air circuit breakers are only used in applications where the voltage is less than 690 volts. These are often referred to as LT (low voltage) applications. On the other hand, vacuum circuit breakers are ideally suited for medium voltage ratings with voltages below 33kV.

Principle of Operation

The moving and static contacts are kept open air in a sealed package in the air circuit breaker. As a result, the arc is quenched by air every time the breaker is opened. Air circuit breakers are easily ionized because they contain less air, which acts as a dielectric. However, vacuum acts as an arc extinguishing medium in vacuum circuit breakers. The ability of a vacuum circuit breaker to break a short circuit is impressive because free electrons cannot exist in a vacuum.

Medium Voltage

The open air pressure is sufficient to extinguish an arc in an air circuit breaker. On the other hand, vacuum breakers must maintain a vacuum pressure of 10-2 to 10-6 torr.

Refill

 Because outdoor air is free, the ACB does not need to be manually refilled. On the other hand, there is no way to automatically refill the vacuum in the VCB. If the vacuum container stops working, you must replace it.

Applications

Air circuit breakers are often used in LTMCCs, secondary feeder circuits for power transformers, and LTPCCs.They are great for indoor use; you can't use them outside. On the other hand, vacuum circuit breakers are used to start more powerful motors.

Arc Chute and Arc Development

 In air circuit breakers, an arc chute is used to prevent arc formation. It divides the arc into smaller parts. Without the arc chute, the ACB would not work. Arcing develops quickly in ACBs.

vacuum circuit breakers do not need an arc chute. In addition, arcs develop less in vacuum circuit breakers because there is nothing else to ionize except the contact material.