LW36-145 Outdoor High Voltage Porcelain Column SF6 Circuit Breaker
2.Rated voltage: 145kV
3.Rated frequency: 50 Hz
4.Rated current: 2000A
LW36-145 Outdoor High Voltage Porcelain Column SF6 Circuit Breaker is an outdoor three-pole outdoor type. It adopts self-charging spring operating mechanism. It has high disconnection capacity, low switching overvoltage, non-reignition capacitor switch, high operating reliability, low maintenance requirements, and can withstand earthquake stress/magnitude up to 7 on the Richter scale.
We can provide the other model sf6 circuit breaker ,such as LW25-126 Outdoor High Voltage Porcelain SF6 Circuit Breaker,LTZ-40.5 Indoor High Voltage SF6 Circuit Breaker and LW9-72.5 Outdoor High Voltage Porcelain SF6 Circuit Breaker,welcome to inquiry .
Advanced Manufacturing and Production
We operate one of the most advanced and standardized assembly line manufacturing facilities in the industry, equipped with the latest technology, enabling us to produce a wide range of high quality electrical products with precision and efficiency. Wecomply with GB 1984-2024 and GB/T11022-2020 standards to ensure the highest quality. Our commitment to excellence is reflected in the durability, reliability, and compatibility of our products.

Product Specifications
Standard technical parameters table
|
No. |
Name |
Unit |
Standard technical parameter values |
Guarantee Value |
|
|
1 |
Vacuum circuit Type |
Porcelain Column |
Porcelain Column |
||
|
2 |
Number of breaks |
Piece |
1 |
1 |
|
|
3 |
Rated voltage |
kV |
145 |
145 |
|
|
4 |
Rated frequency |
Hz |
50 |
50 |
|
|
5 |
Rated current |
A |
2000 |
2000 |
|
|
6 |
Main circuit resistance |
mW |
≤40 |
≤40 |
|
|
7 |
Temperature rise test current |
A |
1.1Ir |
1.1Ir |
|
|
8 |
Rated power frequency withstand voltage/1min |
Across the contact gaps |
kV |
230+70 |
230+70 |
|
To ground |
230 |
230 |
|||
|
Rated lightning impulse withstand voltage (1.2/50ms) peak |
Across the contact gaps |
kV |
550+100 |
550+100 |
|
|
To ground |
550+100 |
550+100 |
|||
|
9 |
Rated short-circuit breaking current |
AC component effective value |
kA |
40 |
40 |
|
Time constant |
ms |
45 |
45 |
||
|
Break times |
Times |
≥20 |
≥20 |
||
|
Prime Minister breaking coefficient |
1.5 |
1.5 |
|||
|
10 |
Rated short circuit making current |
A |
100 |
100 |
|
|
11 |
Rated short-time withstand current and duration |
kA/s |
40/3 |
40/3 |
|
|
12 |
Rated withstand current (peak) |
kA |
31.5/40 |
31.5/40 |
|
|
13 |
Breaking time |
ms |
≤60 |
≤60 |
|
|
14 |
Closing and Opening Time |
ms |
≥80 |
≥80 |
|
|
15 |
openning time (lower limit provided by the manufacturer) |
ms |
≤40 |
≤40 |
|
|
16 |
closing time (lower limit provided by the manufacturer) |
ms |
≤120 |
≤120 |
|
|
17 |
Reclosing current-free gap time |
ms |
300及以上可调 |
300及以上可调 |
|
|
18 |
Average opening speed |
m/s |
5±0.5 |
5.0±0.5 |
|
|
19 |
Average closeing speed |
m/s |
3±0.5 |
3.0±0.5 |
|
|
20 |
NO -Simultaneity of Opening operations |
OP |
≤2 |
≤2 |
|
|
21 |
NO -Simultaneity of Closing operations |
ms |
≤3 |
≤3 |
|
|
22 |
Mechanical stability |
次 |
≥10000 |
≥10000 |
|
|
23 |
Rated operating sequence |
O–0.3s–CO–180s–CO |
O–0.3s–CO–180s–CO |
||
|
24 |
Auxiliary and control circuit short-time power frequency withstand voltage |
kV |
2 |
2 |
|
|
25 |
Radio interference voltage |
uV |
≤500 |
≤500 |
|
|
26 |
Noise Level |
dB |
≤110 |
≤110 |
|
|
27 |
On-site opening and closing of no-load transformer test |
No-load transformer capacity |
MVA |
50 |
50 |
|
No-load excitation current |
A |
0.5~15 |
0.5~15 |
||
|
Test voltage |
kV |
126 |
126 |
||
|
Operating sequence |
10×O and 10×CO |
10×O and 10×CO |
|||
|
28 |
On-site opening and closing of no-load line charging Current test |
Test current |
A |
Determined by the actual line length |
Determined by the actual line length |
|
Test voltage |
kV |
126 |
126 |
||
|
Test conditions |
In principle, the line shall not have pressure relief equipment, such as reactors, lightning arresters, electromagnetic voltage transformers, etc. |
In principle, the line shall not have pressure relief equipment, such as reactors, lightning arresters, electromagnetic voltage transformers, etc. |
|||
|
Operating sequence |
10×(O–0.3s–CO) |
10×(O–0.3s–CO) |
|||
|
29 |
Capacitive current switching test (laboratory) |
Test current |
A |
Line: 31.5; Cable: 140 |
Line: 31.5; Cable: 140 |
|
Test voltage |
kV |
1.4×126/ |
1.4×126/ |
||
|
C1 Grade:LC1 and CC1:24×O, LC2 and CC2:24×CO C2 Grade :LC1 and CC1:48×O, LC2 and CC2:24×O and 24×CO |
C1 Grade /C2 Grade |
C1 |
|||
|
30 |
Switching capability under local fault conditions |
L90 |
kA |
36 |
36 |
|
L75 |
kA |
30 |
30 |
||
|
L60 |
kA |
24 (When the minimum arcing time of L75 is longer than the minimum arcing time of L90 by 5ms) |
24 (When the minimum arcing time of L75 is longer than the minimum arcing time of L90 by 5ms) |
||
|
Operating sequence |
O–0.3s–CO–180s–CO |
O–0.3s–CO–180s–CO |
|||
|
31 |
|
Breaking current |
kA |
10 |
10 |
|
Power frequency recovery voltage |
kV |
2.5×126/ |
2.5×126/ |
||
|
Operating sequence |
方式1:CO-O-O: 方式2:O-O-O |
方式1:CO-O-O: 方式2:O-O-O |
|||
|
32 |
Different-phase ground fault interruption test |
Test current |
kA |
34.6 |
34.6 |
|
Test voltage |
kV |
126 |
126 |
||
|
Operating sequence |
O–0.3s–CO–180s–CO |
O–0.3s–CO–180s–CO |
|||
|
33 |
SF6 gas pressure (gauge pressure at 20℃) |
Highest |
MPa |
0.6 |
0.6 |
|
Rated |
0.6 |
0.6 |
|||
|
Minimum (Latched) |
0.5 |
0.5 |
|||
|
34 |
SF6 gas humidity |
Handover acceptance value |
mL/L |
≤150 |
≤150 |
|
Long-term operation allowable value |
≤300 |
≤300 |
|||
|
35 |
SF6 gas leakage rate |
Year |
≤0.5% |
≤0.5% |
|
|
36 |
SF 6 gas purity |
99.9% |
99.9% |
||
|
37 |
Operating mechanism type or model |
Spring |
Spring |
||
|
Operation mode |
Three-phase mechanical linkage |
Three-phase mechanical linkage |
|||
|
Motor voltage |
V |
AC220 or AC380 |
AC380 |
||
| Closing operation power supply |
Rated Operating voltage |
V |
DC110or DC220 |
DC220 |
|
|
Allowable operating voltage range |
Reliable operation within the range of 85% to 110% rated operating voltage, no operation when the rated voltage is less than 30% |
Reliable operation within the range of 85% to 110% rated operating voltage, no operation when the rated voltage is less than 30% |
|||
|
Number of coils per phase |
pcs |
1 |
1 |
||
|
Steady-state current per coil |
A |
DC110,5A/DC220V,2.0A |
DC220V,2.A |
||
|
Opening operation power supply |
Opening operation power supply Rated operating voltage |
V |
DC110/DC220 |
DC220 |
|
|
Operating voltage allowable range |
65%~120%,30% |
65%~120%,30% |
|||
|
Number of coils per phase |
Piece |
1 |
1 |
||
|
Steady-state current per coil |
A |
DC110,5A/DC220V,2A |
DC220V,2A |
||
|
Heater |
Voltage |
V |
AC 220 |
AC 220 |
|
|
Power per phase |
W |
100 |
100 |
||
|
Spare auxiliary contacts |
Quantity |
A |
Each 10 |
Each 10 |
|
|
Breaking capacity Energy storage time Mass of each phase operating mechanism |
DC110,5A/DC220V,2.5A |
DC110,5A/DC220V,2.5A |
|||
|
Maintenance cycle of the main body |
Year |
≥20 |
≥20 |
||
|
Spring mechnism |
Storage energy time |
s |
≤20 |
≤20 |
|
|
38 |
Phase distance of circuit breaker |
mm |
1700 |
1700 |
|
|
39 |
The quality of the vacuum circuit breaker |
Total mass of circuit breaker including auxiliary equipment |
kg |
1300 |
1300 |
|
Mass of each phase operating mechanism transportation height |
kg |
350 |
350 |
||
|
Mass of each phase SF6 gas |
kg |
10 |
10 |
||
|
Total transportation mass Circuit breaker |
kg |
1400 |
1400 |
||
|
40 |
casing |
(to ground/Across the contact gaps |
mm |
3900 (When 500mm≥average diameter≥ 300mm, multiply by 1.1; when average diameter>500mm, multiply by 1.2) |
3900 (When 500mm≥average diameter≥ 300mm, multiply by 1.1; when average diameter>500mm, multiply by 1.2)
|
|
Dry arc distance |
≥900 |
≥900 |
|||
|
S/P |
≥0.9 |
≥0.9 |
|||
|
41 |
Terminal static load |
Horizontal longitudinal Safety factor |
N |
1250 |
1250 |
|
Horizontal transverse |
750 |
750 |
|||
|
Vertical |
1000 |
1000 |
|||
|
Safety factor |
Static 2.75, dynamic 1.7 |
Static 2.75, dynamic 1.7 |
|||
Operating environment
≤1000M
≤90%
≤35M/s
Level III.Level IV
-20℃-50℃
25K
7 degrees
10mm
1000W/m²
GB/T1984-2014
Product Advantages
LW36-145 Outdoor High Voltage Porcelain Column SF6 Circuit Breaker has many advantages
-
Superior breaking capacity:
When the excitation current is cut, the overvoltage is less than 2 times the operating voltage, and when the charging current is cut, there is no re-breakdown and re-ignition phenomenon;
-
Each pole should be installed on a common circuit breaker base.The pole should be filled with SF6 gas for arc extinguishing and sufficient mechanical and electrical safety factors.sufficient mechanical and electrical safety factors.sufficient mechanical and electrical safety factors.insulation. The design of the arc extinguishing mechanism ensures that all its components have sufficient mechanical and electrical safety factors.
-
Reliable insulation:
The characteristics of SF6 gas do not change over time, and at the same time, the insulating parts and conductive parts in the gas are protected from oxidation, ensuring the temperature operation of the product;
Product Outline Drawing


Shaanxi West Power Tongzhong Electrical Co., Ltd.
Among many offerings, our core product - VTZ Series Vacuum Circuit Breakers stand out for their exceptional quality and performance. Maintenance-free and with a service life of up to 20 years, these products set a new standard in the industry and are known for their simple structure, high reliability, low power consumption and long service life. Meeting and exceeding global standards, They are extensively exported to Central Asia, Southeast Asia, South America, Europe, and other regions.
Hot Tags: lw36-145 outdoor high voltage porcelain column sf6 circuit breaker, China lw36-145 outdoor high voltage porcelain column sf6 circuit breaker manufacturers, suppliers, factory, LW9 72 5 Outdoor High Voltage Porcelain SF6 Circuit Breaker, LW25 126 Outdoor High Voltage Porcelain SF6 Circuit Breaker, outdoor hv ac circuit breaker, high voltage switch equipment
-
LW25-126 Outdoor High Voltage Porcelain SF6 Circuit Breakerview more> -
LW9-72.5 Outdoor High Voltage Porcelain SF6 Circuit Breakerview more> -
24kV Sensorview more> -
GGD AC Low Voltage Distribution Cabinetview more> -
Alternative Design Of ABB Circuit Breakerview more> -
KYN28-24 Indoor Armored Metal-Enclosed Switch Equipmentview more>